Iron Removal

  • electronic controlled valve
    quantity controlled start of regeneration
    calculation of capacity only via hardness
    regeneration with commonly used salt
    unit preassigned
    time-controlled forced regeneration
    nominal size 1“
    nominal pressure 8 bar

    ECOA77_1 1,1 m³/h 77 m³dH
    ECOA105_1 1,4 m³/h 105 m³dH
    ECOA130_1 1,6 m³/h 130 m³dH
    ECOA157_1 2,0 m³/h 157 m³dH
    ECOA210_1 2,5 m³/h 210 m³dH

    suitable for softening of iron and manganese containing water
    Example of use: commercial and industrial water softening applications with concurrent removal of iron, manganese and ammonium

  • electronic controlled valve
    quantity controlled start of regeneration
    calculation of capacity only via hardness
    regeneration with commonly used salt
    unit preassigned
    time-controlled forced regeneration
    nominal size 2“
    nominal pressure 8 bar

    ECOA315_2 4,4 m³/h 315 m³dH
    ECOA472_2 5,6 m³/h 472 m³dH
    ECOA735_2 8,8 m³/h 735 m³dH
    ECOA1102_2 12,8 m³/h 1102 m³dH

    suitable for softening of iron and manganese containing water
    Example of use: commercial and industrial water softening applications with concurrent removal of iron, manganese and ammonium

  • Double water softening units for a continuous soft water supply
    electronic controlled valve
    quantity controlled start of regeneration
    calculation of capacity only via hardness
    regeneration with commonly used salt
    unit preassigned
    time-controlled forced regeneration
    nominla size 1“
    nominal pressure 8 bar

    ECOAD77_1 1,1 m³/h 2 x 77 m³dH
    ECOAD105_1 1,4 m³/h 2 x 105 m³dH
    ECOAD130_1 1,6 m³/h 2 x 130 m³dH
    ECOAD157_1 2,0 m³/h 2 x 157 m³dH

    suitable for softening of iron and manganese containing water
    Example of use: commercial and industrial water softening applications with concurrent removal of iron, manganese and ammonium

  • Double water softening units for a continuous soft water supply
    2 electronic controlled valves
    quantity controlled start of regeneration
    calculation of capacity only via hardness
    regeneration with commonly used salt
    unit preassigned
    time-controlled forced regeneration
    nominal size 6/4“
    nominal pressure 8 bar

    ECOAD315_64 4,4 m³/h 2 x 315 m³dH
    ECOAD472_64 5,6 m³/h 2 x 472 m³dH
    ECOAD735_64 8,8 m³/h 2 x 735 m³dH

    suitable for softening of iron and manganese containing water
    Example of use: commercial and industrial water softening applications with concurrent removal of iron, manganese and ammonium