Refill Combinations

  • for a safe connection to the drinking water pipeline acc. to EN 1717
    System Separator Type BA
    incl. isolating valve
    incl. insulation jacket

    DB300 2,65 m³/h at 1,75 bar pressure loss

    Example of use: Feeding units in warm and cold water installations

  • for a safe connection to the drinking water pipeline acc. to EN 1717

    DVGW and ÖVGW approved
    small dimensions
    outlet without straight connector plug (prevention of recirculation)
    fastening clip and fixing bracket for connection to the drain
    inner profile shape designed for reduction of deposits
    easy startup and checking
    service possible at the installation point

    BA574_12                              1,0 m³/h
    BA574_34                              2,0 m³/h
    BA574_1                                4,5 m³/h
    BA574_54                              5,0 m³/h
    BA574_64                              16 m³/h
    BA574_2                                18 m³/h

    Example of use: Safe separation previous to a treatment installation like softening, dosing,…

  • simple instant flowmeter for monitoring of the feeding quantity

    including seals and screw joints

    KWZ 1/2“                                Qn 1,5
    KWZ 3/4“                                Qn 2,5

    Example of use: Feeding units in hot and cold water systems

  • simple possibility to check the conductivity of water after a demineralization cartridge
    3/4“- model
    display of conductivity green / yellow / red – 230V/50 Hz

    LED5                                      1,0 µS – 20 µS
    LED Flash                              ≤ 80 µS / 80 – 100 µS / > 100 µS

    Example of use: Monitoring of demineralisation cartridges

  • softening by one-way exchange resin
    high capacity
    resin easily exchangeable
    connection 2 x 3/4“ flat sealing
    nominal pressure 8 bar
    suitable for filling too
    also available as a leasing cartridge

    EP4000                                  4 m³ at 10° water hardness
    EP8000                                  8 m³ at 10° water hardness
    EP12000                                12 m³ at 10° water hardness

    Example of use: Feeding units in hot and cold water systems

  • demineralisation by one-way exchange resin
    high capacity
    resin easily exchangeable
    connection 2 x 3/4“ flat sealing
    nominal pressure 8 bar
    suitable for filling too
    also available as a leasing cartridge

    VE2800                                  max. 2,5 m³ at 10° water hardness
    VE5000                                  max. 4,5 m³ at 10° water hardness
    VE7000                                  max. 7,0 m³ at 10° water hardness
    VE12000                                max. 11,0 m³ at 10° water hardness

    Example of use: Feeding units in hot and cold water systems

  • demineralisation by one-way exchange resin
    resin easily exchangeable
    connection 2 x 3/4“ AG
    nominal pressure 8 bar
    with LED5 conductivity indicator (230V)
    range from ≤ 1,0 µS to 20 µS

    VE2800_LED5                       max. 0,8 m³/h
    VE5000_LED5                       max. 1,5 m³/h
    VE7000_LED5                       max. 2,0 m³/h
    VE12000_LED5                     max. 2,0 m³/h

    Example of use: Feeding units in hot and cold water systems

  • demineralisation by one-way exchange resin
    for manufacturing of low-salt water up to 100 µS
    resin easily exchangeable
    connection 2 x 3/4“ AG
    nominal pressure 8 bar
    with LED5 conductivity indicator, battery operated
    life time 5 years
    range from ≤ 80 µS / 80 to100 µS / > 100 µS

    VE2800_LED Flash               max. 1,8 m³/h
    VE5000_LED Flash               max. 2,0 m³/h
    VE7000_LED Flash               max. 2,0 m³/h
    VE12000_LED Flash             max. 2,0 m³/h

    Example of use: Feeding units in hot and cold water systems

  • demineralisation by one-way exchange resin
    for manufacturing of demineralsed water
    resin easily exchangeable
    connection 2 x 3/4“ AG
    nominal pressure 8 bar
    with digital conductivity indicator, programmable
    relay output (optional)

    VE2800/DIG                           max. 1,8 m³/h
    VE5000/DIG                           max. 2,0 m³/h
    VE7000/DIG                           max. 2,0 m³/h
    VE12000/DIG                         max. 2,0 m³/h

    VE2800/DIGR                                   max. 1,8 m³/h relay 1xUM
    VE5000/DIGR                                   max. 2,0 m³/h relay 1xUM
    VE7000/DIGR                                   max. 2,0 m³/h relay 1xUM
    VE12000/DIGR                      max. 2,0 m³/h relay 1xUM

    Example of use: Feeding units in hot and cold water systems
    demineralisation by one-way exchange resin
    for manufacturing of demineralsed water
    resin easily exchangeable
    connection 2 x 3/4“ AG
    nominal pressure 8 bar
    with digital conductivity indicator, programmable
    relay output (optional)

    VE2800/DIG                           max. 1,8 m³/h
    VE5000/DIG                           max. 2,0 m³/h
    VE7000/DIG                           max. 2,0 m³/h
    VE12000/DIG                         max. 2,0 m³/h

    VE2800/DIGR                                   max. 1,8 m³/h relay 1xUM
    VE5000/DIGR                                   max. 2,0 m³/h relay 1xUM
    VE7000/DIGR                                   max. 2,0 m³/h relay 1xUM
    VE12000/DIGR                      max. 2,0 m³/h relay 1xUM

    Example of use: Feeding units in hot and cold water systems

  • including pre-filter 20 µm
    including instant flowmeter
    including salt / brine tank 25 lt.
    high capacity
    regenaration launching manually
    fully automated regeneration sequence
    inlet Gardena/M
    outlet KFE
    nominal pressure 8 bar

    F80 SENIOR                         8 m³ soft water           FR 1,4 – 2,1 m³/h

    Example of use: Filling acc. to ÖNORM H-5195