Measurement and control technology

ISO Badge & Badge mit Gründungsjahr

It’s all about the right amount

To comply with the water parameters required by standards and legal regulations, measurement and control technology must be used. Our components allow you to control the following influencing factors:

  • Quantities (added, flow rate)
  • Conductivity
  • pH value

The following controllers are available for implementing the respective regulations:

  • 1-Kanal & 2-Kanal & 5-Kanal Controller LDxx
    • Compact device with microprocessor technology
      1 channel + temperature (depending on version)
      Highest process reliability across a wide range of applications
      For wall mounting in an IP65-rated housing
      Also available for front panel mounting (96 x 96 mm)
      Proportional pulse frequency output (for dosing pump control)
      Output relay
      Standby input

    LDPH housing IP 65 pH measurement
    LDRH housing IP 65 redox measurement
    LDCD housing IP 65 conductivity measurement
    LDCL housing IP 65 Cl2 measurement

    JCPH Front 96 x 96 mm pH measurement
    JCRH Front 96 x 96 mm Redox measurement
    JCCD Front 96 x 96 mm Conductivity measurement
    JCCL Front 96 x 96 mm Cl2 measurement

    Suitable for monitoring parameters in liquid analysis
    Application example: Cooling towers, pH, Cl2 or redox measurements with simultaneous monitoring of limit values
    Catalog: 10_03

  • 1-Kanal & 2-Kanal & 5-Kanal Controller LDxx
    • Compact device with microprocessor technology
      2-channel + temperature (depending on version)
      First channel pH measurement
      Temperature-compensated measurements
      Innovative user interface with click wheel
      Maximum process reliability across a wide range of applications
      For wall mounting in an IP65-rated housing
      Proportional pulse frequency output (for dosing pump control)
      Output relay
      4-20 mA current output (optional)
      Standby input

    LDPHRH pH + Redox measurement
    LDPHCL pH + Cl2 measurement
    LDPHCD pH + Conductivity measurement
    LDPHCDIND pH + Inductive conductivity measurement

    Suitable for monitoring parameters in liquid analysis
    Application example: Cooling towers, chlorine, conductivity, or redox potential measurements with simultaneous pH monitoring
    Catalog: 10_04

  • 1-Kanal & 2-Kanal & 5-Kanal Controller LDxx
    • Compact device with microprocessor technology
      5-channel + temperature
      Innovative user interface with click wheel
      Also available with remote maintenance (USB – RS485 – Ethernet – GSM – Internet)
      Highest process reliability across a wide range of applications
      For wall mounting
      Proportional pulse frequency outputs (for dosing pump control)
      Output relay
      Standby input

    MAX 5 Temperature + up to 5 of the following measured variables:

    • pH
    • Redox potential
    • Conductivity
    • Turquoise
    • Dissolved oxygen
    • Chlorine dioxide
    • Free chlorine
    • Total chlorine
    • Organic chlorine
    • Ozone
    • Bromine
    • Hydrogen peroxide

    Suitable for multiple parameter monitoring in liquid analysis
    Application example: all applications where multiple parameters need to be measured cost-effectively
    Catalog: 10_05

  • 1-Kanal & 2-Kanal & 5-Kanal Controller LDxx
    • Compact device with microprocessor technology
      Monitoring of all parameters of the customer-specific pre-configured system
      2-channel + temperature
      Innovative user interface with click wheel
      Maximum process reliability across a wide range of applications
      For wall mounting
      Proportional pulse frequency outputs (for dosing pump control)
      Output relay
      4-20 mA current output (optional)
      Standby input

    MTOWER Temperature + up to 2 of the following measured variables (conductive electrode)
    MTOWERIND Temperature + up to 2 of the following measured variables (inductive electrode)

    • Conductivity
    • pH
    • Redox potential
    • Chlorine

    Application example: Cooling towers
    Catalog: 10_06

  • 3-Kanal Controller (mit Temperatur) für Kühltürme MTOWER+
    • Compact device with microprocessor technology
      Monitoring of all parameters of the customer-specific pre-configured system
      3-channel + temperature
      Innovative user interface with click wheel
      Also available with remote maintenance (USB – RS485 – Ethernet – GSM – Internet)
      Highest process reliability across a wide range of applications
      For wall mounting
      Proportional pulse frequency outputs (for dosing pump control)
      Output relay
      4-20 mA current output (optional)
      Standby input

    MTOWER+ Temperature + up to 3 of the following measured variables (conductive electrode)
    MTOWERIND+ Temperature + up to 3 of the following measured variables (inductive electrode)

    • Conductivity
    • pH
    • Redox potential
    • Chlorine

    Application example: Cooling towers
    Catalog: 10_07

  • Wasser-Messtechnik Zubehör
    • Inductive conductivity probes
      Conductive conductivity cells
      pH/redox electrodes
      Open or membrane-covered amperometric cells
      Filters for measuring sections
      Fittings, electrode holders,…

    Catalog: 10_08 / 10_09 / 10_10 / 10_11

Why you can rely on our expertise

Comprehensive expertise in water treatment

With over 70 years of experience, we offer customized solutions for all water treatment needs, from heating and steam boiler systems to drinking water systems.

Sustainable and efficient renovation

Our innovative renovation methods minimize operational disruptions and ensure long-lasting protection of your water systems, while conserving resources.

High-quality products for every need

We offer a wide range of chemical additives, cleaning agents and protective agents that meet the highest quality standards and are suitable for a variety of applications.

Personal customer support

Our experienced team is on hand to provide expert advice and individual service to optimally meet your specific requirements.