What heating and cooling system installers know
As an installer for heating & cooling system or plant engineer, you put your name behind every project. The system water in heating and cooling installations is a critical factor—one that is all too often underestimated until it is too late.
Limescale deposits in heat exchangers
Precipitation of hardness minerals measurably increases energy consumption and shortens the service life of equipment. Using desalinated fill water prevents scale formation from the very start.
Undetected corrosion in the heating circuit
In closed-loop systems, corrosion occurs due to residual oxygen and incorrect conductivity—often remaining undetected for years until costly damage arises.
Missing documentation following VDI 2035
At the time of commissioning, analysis data, logs, and certificates are frequently missing. In the absence of documentation that complies with standards, warranty claims are forfeited.
Check antifreeze concentration
In refrigeration systems, the glycol concentration tends to drift over the years. Levels that are too low risk damaging the equipment—regular testing is essential.
Our services for
heating and cooling technology.
In heating circuits, hard water leads to limescale deposits that impair heat transfer and increase energy consumption. We supply water softening units, demineralization systems, and reverse osmosis plants, correctly sized for your specific project—including commissioning in compliance with relevant standards.
Softened and demineralized water is inherently corrosive. Without appropriate corrosion inhibitors, metal components in heating circuits will be subject to damage. Our proprietary products, FLUTREN and AKORRIT, provide reliable protection for steel, copper, and aluminum components and are suitable for use in closed systems in accordance with the VDI 2035 standard.
Limescale deposits, corrosion, and microbial growth in refrigeration systems and closed cooling circuits reduce efficiency and compromise operational reliability. We treat your cooling water using MINIPOL and, where necessary, provide a biocide treatment for open cooling towers.
Before a system is filled or renovated, an analysis is required. We conduct water analyses in accordance with ÖNORM and VDI guidelines—either on-site or in the laboratory—and provide the documentation you need for standards-compliant commissioning and subsequent verification.
70+ Years
Experience · since 1952
ISO 9001
Certified · Quality Management
VDI 2035
Execution in compliance with standards
Minimal.
Business interruption
FLUTREN
Corrosion inhibitor for closed heating circuits – provides reliable protection for steel, copper, and aluminum, and stabilizes the pH value in accordance with VDI 2035.
AKORRIT
Corrosion inhibitor for closed heating circuits containing mixed materials (steel, copper, aluminum).
MINIPOL
Hardness stabilizer and dispersing agent for preventing limescale deposits in heat exchangers.
ANTIFROST-PRO
Glycol-based antifreeze for refrigeration and solar thermal systems, with integrated corrosion inhibition.
KALZITIN
Acid-free descaler for cleaning calcified heat exchangers and heat pumps during operation.
Standard-compliant
water treatment.
Every process—from the heating circuit to the refrigeration unit—is carried out in accordance with the applicable European and Austrian regulations.
In Germany and Austria, the initial filling and operation of hot-water heating systems are primarily governed by the VDI 2035 guideline and the ÖNORM H 5195 standard. These define permissible limits for water hardness, conductivity, and pH value.
For refrigeration systems and closed cooling circuits, the standards ÖNORM M 7753 (cooling water) and VDI 2047 (re-cooling systems, hygiene) also apply. We document all key parameters in a commissioning report, which can be added directly to the system’s documentation file.
| VDI 2035 Scale formation and corrosion in hot-water heating systems |
ÖNORM H 5195 Prevention of damage caused by corrosion and scale formation
|
| ÖNORM M 7753 Cooling Water — Requirements and Treatment |
VDI 2047 Cooling Towers — Hygiene and Safety |
Frequently Asked Questions.
The questions that installers and refrigeration system contractors ask us most frequently.
Dial directly
Mon–Thu 08:00 – 17:00 · Fri until 14:00
Dr. Ing. Franz Böhm Ges.m.b.H.
Industriestraße 21 · 2325 Himberg
office@drboehm.at